RTC Date Write

<< Click to Display Table of Contents >>

Navigation:  STM32F4 Target > Block References > On-chip Peripherals > RTC >

RTC Date Write

Previous pageReturn to chapter overviewNext page

User Interface

How this block appears in a Simulink model?

rtc_date_write_block

rtc_date_write_mask

Configuration item

Selectable option/ Value

Description

Format

BIN | BCD

Specify output ports is binary or BCD format.

Sample time(sec)

-1 (Inherited) or specify

Sample time for block

Input port

Name

Description

Date

Valid value is 1 to 31, 1 to 30, 1 to 28 or 1 to 29 depend on Month and Year.

Month

Month, valid value is 1 to 12.

Year

Year, Valid value is 0 to 99. This Year number is offset from Year 2000.

Demos

Date/ Time display

Date and Time configuration demo